Technical Specifications

SPL
113 dB

Amplifier Power
150 W Bass (Class AB) + 120 W Midrange (Class AB) + 120 W Treble (Class AB)

Frequency Response
23 Hz - 40 kHz ("-6 dB")

Accuracy of Frequency Response
± 1 dB (29 Hz - 20 kHz)

Dimensions
H 593 x W 357 x D 347 mm, with Iso-Pod™ (view in inches)

Weight
27.5 kg / 60.6 lb

Connections
1 x XLR Analog Input
1 x XLR AES/EBU Input
1 x XLR AES/EBU Output
2 x RJ45 Control
8260 product specifications
Technical Specifications
A masterpiece of electro-acoustic design, the 8260A remains a milestone achievement in coaxial monitoring and mid-field precision.
The Genelec 8260A was in production between 2010 and 2019. It was replaced by the 8361A model.

System Specifications
Frequency Response
29 Hz - 20 kHz (± 1 dB)
Low cutoff -6dB
23 Hz
High cutoff -6dB
40 kHz

SPL
Peak SPL Maximum peak SPL output per pair on top of console at 1 m with music material.
≥123 dB
Short term max SPL Maximum short term sine wave SPL output at 1 m on axis in half space, averaged from 100 Hz to 3 kHz.
≥113 dB
Self-generated noise
Self-generated noise Self generated noise level in free field at 1 m on axis (A-weighted).
≤5 dB SPL
Weight
Weight27.5 kg (60.6 lb)
Dimensions
Height
570 mm
Height with Iso-Pod
593 mm
Width
357 mm
Depth
347 mm

Enclosure
Enclosure material
Die cast aluminium
Enclosure type
Reflex port
Directivity

Harmonic distortion
Group delay
The latency at high frequencies from the input to the acoustic output, measured in the analog input:
Extended Phase Linearity in GLM set to OFF
4.9 ms
In Genelec performance graphics, the time of converting the from an electronic input signal to the acoustic output in a Genelec monitor is described by two factors – latency and group delay. The group delay factor can be read in the graphics for a specific frequency. The total frequency-specific input-to-output delay is a sum of the latency and group delay factors. To understand the significance of this total delay, consider that moving a loudspeaker away by 1 meter creates an additional delay of about 3 ms.
Amplifier Section
Amplifiers
150 W Class AB
120 W Class AB
120 W Class AB
Mains voltage
100, 120, 220 or 230VAC 50/60Hz according to region
Power consumption
Idle
≤26 W
Full output
330 W
Signal processing section
Connectors
Input Analog signal input connector XLR female (10 kOhm input load impedance).
Input XLR female (conforms to IEC 60958-4)
Output XLR male (conforms to IEC 60958-4)
2 x Control Two CAT5 (RJ45) GLM Network connectors for computer control using the Genelec Loudspeaker Manager (GLM) software.